ELCOMETER (DFT Meter) Digital Coating Thickness Gauge
ELCOMETER (DFT Meter) Digital Coating Thickness Gauge
We offer a broad range of dft meter coating thickness gauge elcometer, which contain 456 coating thickness gauges along with a basic menu screen option. These are available variety of combinations of top, standard and basic functionally along with a wide range of separate plug in probes and integral (built in) as per the needs of the application. Our range of product consit of the following range of separate probe options, plug in probes, gauge feature, standard, separate gauges, minature and integral gauges.
Dry Film Thickness – Digital Coating Thickness Gauge Elcometer 456 Range: 0-1500μm (0-60mils) Accuracy*: ±1-3% or ±2.5μm (±0.1mil), Resolution: 0.1μm: 0-100μm; 1μm: 100-1500μm (0.01mil: 0-5mils; 0.1mil: 5-60mils), Model B Model S Model T. Elcometer 456 Ferrous Integral A456CFBI1 A456CFSI1 A456CFTI1. Elcometer 456 Non-Ferrous Integral A456CNBI1 Separate gauges with N2 PINIP™ Probe & N2 PINIP™ Probe. Elcometer 456 Dual FNF Integral A456CFNFBI1 A456CFNFSI1 A456CFNFTI1. Dry Film Thickness – Digital Coating Thickness Gauge Elcometer 456 Range: 0-5mm (0-200mils) Accuracy*: ±1-3% or ±20μm (±1.0mil) Resolution: 1μm: 0-1mm; 10μm: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils) Model B Model S Model T Elcometer 456 Ferrous Integral A456CFBI2 Separate gauges with F2 PINIP™ Probe & F2 PINIP™ Probe. Digital Coating Thickness Gauge Elcometer 456 Range: 0-13mm (0-500mils) Accuracy*: ±1-3% or ±50μm (±2.0mils) Resolution: 1μm: 0-2mm; 10μm: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils) Model B Model S Model T. Elcometer 456 Ferrous Integral A456CFBI3 Separate gauges F3 PINIP™ Probe & F3 PINIP™ Probe. Digital Coating Thickness Gauge Elcometer 456 Separate Model Options : Model B Model S Model T. Elcometer 456 Ferrous Separate A456CFBS A456CFSS A456CFTS. Elcometer 456 Non-Ferrous Separate A456CNBS A456CNSS A456CNTS. Elcometer 456 Dual FNF Separate A456CFNFBS A456CFNFSS A456CFNFTS. Probe range Scale 0.5: Range: 0-500μm / 0-20mils Ferrous (F) Mini Probe – Straight, 45mm (1.77”) long T456CFM3—A 6mm (0.24”) 3mm (0.12”), Mini Probe – 90°, 45mm (1.77”) long T456CFM3R90A 16mm (0.63”) 3mm (0.12”), Mini Probe – 45°, 45mm (1.77”) long T456CFM3R45A 18mm (0.71”) 3mm (0.12”), Mini Probe – Straight, 150mm (5.90”) long T456CFM3—C 6mm (0.24”) 3mm (0.12”), Mini Probe – 90°, 150mm (5.90”) long T456CFM3R90C 16mm (0.63”) 3mm (0.12”), Mini Probe – 90°, 300mm (11.8”) long T465CFM3R90D 16mm (0.63”) 3mm (0.12”), Mini Probe – 45°, 300mm (11.8”) long T456CFM3R45D 18mm (0.71”) 3mm (0.12”). Non-Ferrous (N) Mini Probe – Straight, 45mm (1.77”) long T456CNM3—A 6mm (0.24”) 4mm (0.16”), Mini Probe – 90°, 45mm (1.77”) long T456CNM3R90A 16mm (0.63”) 4mm (0.16”), Mini Probe – Straight,150mm (5.90”) long T456CNM3—C 6mm (0.24”) 4mm (0.16”), Mini Probe – 90°, 150mm (5.90”) long T456CNM3R90C 16mm (0.63”) 4mm (0.16”), Mini Probe – 90°, 400mm (15.7”) long T456CNM3R90E 16mm (0.63”) 4mm (0.16”). Non-Ferrous – Graphite (N) Mini Probe – 90° Graphite, 45mm (1.77”) long T456CNMG3R90A 16mm (0.63”) 4mm (0.16”), Mini Probe – 90° Graphite, 150mm (5.90”) long T456CNMG3R90C 16mm (0.63”) 4mm (0.16”), Mini Probe – 90° Graphite, 400mm (15.7”) long T456CNMG3R90E 16mm (0.63”) 4mm (0.16”). Probe range Scale 1: Range: 0-1500μm / 0-60mils Ferrous (F) Straight Probe T456CF1S 85mm (3.35”) 4mm (0.16”), Straight Probe, sealed T456CF1E 85mm (3.35”) 4mm (0.16”), Ultra/Scan Probe T456CF1U 86mm (3.38”) 15mm (0.59”), Right Angle Probe T456CF1R 28mm (1.10”) 4mm (0.16”), Mini Probe – 90°, 45mm (1.77”) long T456CFM5R90A 16mm (0.63”) 4mm (0.16”), Mini Probe – 90°, 45mm (1.77”) long, sealed T456CFME5R90A 16mm (0.63”) 4mm (0.16”), Mini Probe – 90°, 45mm (1.77”) long, 2m cable, sealed T456CFME5R90A-2 16mm (0.63”) 4mm (0.16”), PINIP™ Integral Probe T456CF1P 170mm (6.69”) 4mm (0.16”). Non-Ferrous (N) Straight Probe T456CN1S 85mm (3.35”) 4mm (0.16”), Right Angle Probe T456CN1R 28mm (1.10”) 4mm (0.16”), Mini Probe – 90°, 45mm (1.77”) long T456CNM5R90A 16mm (0.63”) 4mm (0.16”), Mini Probe – 90°, 150mm (5.90”) long T456CNM5R90C 16mm (0.63”) 4mm (0.16”), Mini Probe – 90°, 400mm (15.7”) long T456CNM5R90E 16mm (0.63”) 4mm (0.16”), Anodiser Probe T456CN1AS 100mm (3.94”) 4mm (0.16”), PINIP™ Integral Probe T456CN1P 180mm (7.09”) 4mm (0.16”). Ferrous & Non-Ferrous (FNF) Straight Probe T456CFNF1S 88mm (3.46”) F: 4mm (0.16”) N: 6mm (0.24”) Straight Probe, armoured cable T456CFNF1ARM 185mm (7.28″) F: 4mm (0.16″) N: 6mm (0.24″) Ultra/Scan Probe T456CFNF1U 89mm (3.50”) 15mm (0.59”), Right Angle Probe T456CFNF1R 38mm (1.50”) F: 4mm (0.16”) N: 6mm (0.24”), PINIP™ Integral Probe T456CFNF1P 180mm (7.09”) F: 4mm (0.16”) N: 6mm (0.24”). Probe range Scale 2: Range: 0-5mm / 0-200mils Ferrous (F) Straight Probe T456CF2S 89mm (3.50”) 8mm (0.32”), Straight Probe, armoured cable T456CF2ARM 138mm (5.43”) 8mm (0.32”), Ultra/Scan Probe T456CF2U 90mm (3.54”) 15mm (0.59”), Right Angle Probe T456CF2R 32mm (1.26”) 8mm (0.32”), Telescopic Probe – 56 -122cm (22 – 48”) long T456CF2T 36mm (1.42”) 8mm (0.32”), Soft Coating Probe T456CF2B 89mm (3.50”) 8mm (0.32”), Waterproof Probe, 1m (3’) cable T456CF2SW 138mm (5.43”) 8mm (0.32”), Waterproof Probe, 5m (15’) cable T456CF2SW-5 138mm (5.43”) 8mm (0.32”), Waterproof Probe, 15m (45’) cable T456CF2SW-15 138mm (5.43”) 8mm (0.32”), Waterproof Probe, 30m (98’) cable T456CF2SW-30 138mm (5.43”) 8mm (0.32”), Waterproof Probe, 50m (164’) cable T456CF2SW-50 138mm (5.43”) 8mm (0.32”), Waterproof Probe, 75m (250’) cable T456CF2SW-75 138mm (5.43”) 8mm (0.32”), PINIP™ Integral Probe T456CF2P 174mm (6.85”) 8mm (0.32”), Hi-Temperature PINIP™ Probe – 250°C (480°F) T456CF2PHT 174mm (6.85”) 8mm (0.32”). Non-Ferrous (N), Straight Probe T456CN2S 88mm (3.46”) 14mm (0.55”), PINIP™ Integral Probe T456CN2P 185mm (7.28”) 14mm (0.55”). Probe range Scale 3: Range: 0-13mm / 0-500mils Ferrous (F), Straight Probe T456CF3S 102mm (4.02”) 14mm (0.55”), PINIP™ Integral Probe T456CF3P 184mm (7.24”) 14mm (0.55”), Non-Ferrous (N) Straight Probe T456CN3S 170mm (6.69”) 35mm (1.38”). Probe range Scale FM7: Range: 0.6-3.8mm / 25-150mils Ferrous (F) Mini Probe – 45°, 45mm (1.77”) long T456CFM7R45A 20mm (0.79”) 6.5 mm (0.26’’). Probe range Scale 6: Range: F: 0-25mm / 0-980mils N: 0-30mm/ 0-1220mils Ferrous (F) Straight Probe T456CF6S 150mm (5.90”) 51 x 51mm2 (2 x 2 inch2) Straight Probe, armoured cable T456CF6ARM 190mm (7.48”) 51 x 51mm2 (2 x 2 inch2) Non-Ferrous (N) Straight Probe T456CN6S 160mm (6.30”) 58mm (2.29”), Straight Probe, armoured cable T456CN6ARM 200mm (7.87″) 58mm (2.29”). Probe range Scale 7: Range: 0-31mm / 0-1220mils Ferrous (F) Straight Probe, armoured cable T456CF7ARM 200mm (7.87”) 55 x 55mm2 (2.17 x 2.17 inch2)
Elcometer 456 IPC Dry Film Thickness Gauge A456CFI1-IPC . The Elcometer 456 Industrial Protective Coating Thickness Gauge is pre-calibrated to measure DFT on shot or grit blasted steel substrates. Pre-calibrated with 4 profile ranges: Profile Metric Imperial, Smooth 0-25μm 0-1mil, Fine 25-60μm 1-2mils, Medium 60-100μm 2-3mils, Coarse >100μm 3-4mils. Built In Probe Type Ferrous, Reading Rate 70+ readings per minute, Range 0 – 1500μm (0 – 60mils), Resolution 10μm / 1mil (where 5μm / 0.5 mil is rounded up), Accuracy** ±5%, Minimum Substrate Thickness 300μm (12mils), Elcometer Limited Manchester England India.
Elcometer 415 Paint & Powder Coating Thickness Gauge. The Elcometer 415 Industrial Paint & Powder Thickness Gauge provides simple, fast and accurate coating thickness measurements on smooth & thin industrial paint and powder coated surfaces. Model B Part Number A415CFBI, Model B A415CFNFBI, Model TA415CFTI, Model TA415CFNFTI. Built in Probe Type Ferrous Ferrous/Non Ferrous Ferrous Ferrous/Non Ferrous Live Data Output USB USB Bluetooth® & USB Bluetooth® & USB, On Screen Statistics Number of readings (n), Average/Mean (x), Lowest reading (Lo), Highest reading (Hi), Fast Accurate Reading Rate 60+ readings per minute, Measurement Range: 0 – 1000μm (0 – 40mils), Accuracy3 ±1-3% or ±2.5μm (±0.1mil), Resolution 0.1μm: 0 -100μm; 1μm: 100 – 1000μm (0.01mil: 0 – 5mils; 0.1mil: 5 – 40mils), Minimum Substrate Thickness Steel: 300μm (12mils) Aluminium: 100μm (4mils) – FNF gauges only, Operating Temperature -10 to 50°C (14 to 122°F), Relative Humidity (RH): 0 to 95%. Accessories : T99916925 Calibration Check Piece; Steel (Ferrous) T99916901 Calibration Check Piece; Aluminum (Non-Ferrous), T99022255-1 Foil Set; 0-1000μm (0 – 40mils), T99022255-1C Certified Foil Set; 0 – 1000μm (0 – 40 mils), T99921325 USB Cable, T99922341 Self Adhesive Screen Protectors (Pack of 10). ELCOMETER 415 A415FNFI1 Digital Paint and Powder Gauge & Elcometer 415 A415FNFI1AUTO Automotive Gauge. Elcometer 311 Automotive Paint Gauge. The Elcometer 311 Automotive Paint Meter is the fastest automotive paint gauge on the market today, used to instantly measure paint thickness and provide an indication of the overall condition of paint work. Model B A311CFBI Steel (F), Model B A311CFNFBI Steel & Aluminium (FNF), Model T A311CFNFTI Steel & Aluminum (FNF), Live Data ouput via Bluetooth® or USB, On screen statistics Number of readings (n), Mean/Average (x), Lowest reading (Lo), Elcometer Index Value (EIV), Fast accurate reading rate 60+ readings per minute Measurement Range 0-500μm / 0-20mils, Accuracy4 ±5% or ±20μm (1.0mil), Resolution 10μm (0.5mil), Minimum Substrate Thickness5 Steel: 800μm (30mils) Aluminium: 300μm (12mils) – FNF gauges only. ELCOMETER 311 A311FM, A311FNFM Automotive Refinishing Gauge. elcometer dry film thickness gauge, elcometer coating thickness gauge, elcometer wiki, what is elcometer, elcometer price, elcometer 456 price in india, elcometer working principle, elcometer india, dft meter elcometer, elcometer 456 coating thickness gauge price, elcometer supplier, elcometer india, elcometer price in india, elcometer price list. Elcometer 355 Digital Coating Thickness Gauge. The Elcometer 355’s watchwords are accuracy, simplicity, versatility and durability making this a true state of the art hand-held measuring system packed with time-saving and cost-cutting features. A355—-S Elcometer 355 Standard Coating Thickness Gauge, A355—-T Elcometer 355 Top Coating Thickness Gauge. Probe Range Scale 1Range: 0-1500μm (0-60mils) Accuracy*: ±1% or ±1μm (±0.04mil) Resolution: 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1500μm (0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils) F1 Standard T35511952 85mm (3.35”) 6mm (0.24”), F1 Right Angle T35511953 28mm (1.10”) 6mm (0.24”), F1 Telescopic T35511959 30mm (1.18”) 6mm (0.24”), N1 Standard T35511982 85mm (3.35”) 8mm (0.31”). Scale 2 Range: 0-5mm (0-200mils) Accuracy*: ±1% or ±5μm (±0.2mil) Resolution: 2μm: 0-500μm; 5μm: 500-5000μm (0.1mil: 0-20mils; 0.2mil: 20-200mils) F2 Standard T35511954 89mm (3.50”) 10mm (0.39”), F2 Telescopic T35511960 36mm (1.42”) 10mm (0.39”), N2 Standard T35511984 88mm (3.46”) 18mm (0.71”). Scale 3 Range: 0-13mm (0-500mils) Accuracy*: ±2% or ±30μm (±1mil) Resolution: 5μm: 0-1mm; 10μm: 1-13mm (0.2mil: 0-40mils; 0.2mil: 40-500mils) F3 Standard T35511956 102mm (4.02”) 18mm (0.71”). Scale 4 Range: 0-250μm (0-10mils) Accuracy*: ±1% or ±1μm (±0.04mil) Resolution: 0.1μm: 0-250μm (0.005mil: 0-10mils) F4 Standard T35511950 85mm (3.35”) 4mm (0.16”), F4 Right Angle (long) T35511951 18mm (0.71”) 3mm (0.12”), N4 Standard T35511980 90mm (3.54”) 8mm (0.31”). Scale 5 Range: 0-800μm (0-32mils) Accuracy*: ±1% or ±2μm (±0.08mil) Resolution: 1μm: 0-800μm (0.1mil: 0-32mils) F5 (Rebar) T35511962 85mm (3.35”) 4mm (0.16”). Scale 6 Range: 0-25mm (0-1000mils) Accuracy*: ±2% or ±100μm (±4mils) Resolution: 10μm: 0-5mm, 50μm: 5-25mm (0.5mil: 0-200mils, 2mil: 200-1000mils) F6 Standard T35511964 150mm (5.9”) 51mm (2.0”)
STANDARDS: AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 5599, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, JIS K 5600-1-7, NF T30-124,SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32